Work out how much heat your cellar actually gains, then size the cooling unit for the ambient temperature it will really face — not the 90°F in the brochure.
Enter your room dimensions to see the load.
Heat enters a cellar four ways, and the total of all four is what the cooling unit has to remove every hour:
We then add a 15% safety margin, because real rooms have thermal bridges, gaps and imperfect assumptions. Finally we derate for ambient: a unit rated at 90°F loses roughly a tenth of its rated capacity for each 10°F above that, so a 105°F garage needs meaningfully more nameplate capacity than the same room in a cool basement.
It assumes steady state. When you first load 300 bottles at 70°F into a 55°F cellar, the cooling unit faces a large one-time pull-down load — allow 24-48 hours, and don't panic-size the unit for it. It also assumes no active moisture control: humidity management is a separate question, covered in temperature and humidity.
For anything above about 2 tons (24,000 BTU/h), or any build using refrigerant lines, get a refrigeration engineer to sign off on the design. The arithmetic here tells you what to ask them, not what to skip.